Supported Cabinets |
N63E-22 |
N63E-22, N66E-22 |
N63E-22 |
Board Configuration |
Control board slots: 9, 10
Service board or upstream interface board slots: 1 to 8, 11 to 19
Universal interface board slot: 0
Power board slots: 20, 21 |
Control board slots: 8, 9
Service board or upstream interface board slots: 1 to 7
Universal interface board slot: 0
Power board slots: 10, 11 |
Control board slots: 3, 4
Service board or upstream interface board slots: 1 to 2
Does not support universal interface board
Power board slot: 0 |
Dimensions
(W x D x H, mm) |
11U high and 21 inches wide
Excluding mounting brackets: 493 x 287 x 486
Including mounting brackets: 535 x 287 x 486 |
6U high and 19 inches wide
Excluding mounting brackets: 442 x 268.7 x 263.9
Including IEC mounting brackets: 482.6 x 268.7 x 263.9
Including ETSI mounting brackets: 535 x 268.7 x 263.9 |
2U high and 19 inches wide
Excluding mounting brackets: 442 x 268.7 x 88.1
Including IEC mounting brackets: 482.6 x 268.7 x 88.1
Including ETSI mounting brackets: 535 x 268.7 x 88.1 |
Maximum Weight (including mounting brackets) |
45 kg |
26 kg |
9.4 kg |
Maximum Input Current |
60A |
40A |
DC power supply: 20A
AC power supply: 8A |
Power Supply Modes |
DC power support (dual for backup) |
DC power support (dual for backup) |
DC power support (dual for backup)
AC power supply + battery for backup |
Working Voltage Range |
-38.4V to -72V DC |
-38.4V to -72V DC |
DC power supply: -38.4V to -72V
AC power supply: 100V to 240V |
Rated voltage |
-48 V / -60 V |
-48 V / -60 V |
DC power supply: -48V/-60V
AC power supply: 110V/220V |
Ambient Temperature |
-40°C to +65°C*. The EA5800 can start up at a lowest temperature of -25°C
Note: The 65°C temperature refers to the highest temperature measured at the air intake vent of service subrack. |
Ambient Humidity |
5% RH to 95% RH |
Atmospheric Pressure |
70 kPa to 106 kPa |
70 kPa to 106 kPa |
70 kPa to 106 kPa |
Altitude |
4,000m The air density varies with the altitude and will affect the heat dissipation of a device. Therefore, the working environment temperature of the EA5800 varies with the altitude. |
Switching Capacity of the Control Board (load sharing mode) |
3.6 Tbit/s |
3.6 Tbit/s |
480 Gbit/s |
Maximum Bandwidth per Service Slot (load sharing mode) |
100 Gbit/s |
100 Gbit/s |
80 Gbit/s |
System Layer 2 Packet Forwarding Rate (load sharing mode) |
5,298 Mpps |
5,298 Mpps |
714 Mpps |
Maximum Number of Concurrent 4K Video Users |
16,000 |
8,000 |
2,000 |
Maximum Number of MAC Addresses |
262,143 |
262,143 |
262,143 |
Maximum Number of ARP/Routing Entries |
131,072 |
131,072 |
131,072 |
Switching/Forwarding Delay |
Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
Bit Error Rate (BER) in full load |
A BER smaller than 10e-7 for a port that transmits data in full load. |
System Reliability Specifications |
System availability for the typical configuration: > 99.999%
Mean Time Between Failures (MTBF): About 45 years.
Note: Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of the EA5800 is only for reference. The average repair time for Field Replaceable Units (FRUs) is about 2 hours. The preceding values are only for reference. For details, contact the related Huawei engineers. |
GPON Ports |
272 |
112 |
32 |
XG-PON Ports/ XGS-PON Ports |
136 |
56 |
16 |
GE/FE Ports |
816 |
336 |
96 |
10 GE Ports |
408 |
168 |
16 |